Large Area Solar Simulator OEM3-6S

$0.00

Category: Tag:

Overview

lA modern LC (Capacitance & Inductance) circuit power source guarantees the spectrum quality

lThe customized AM 1.5 filter guarantees the spectrum up to Grade A according to IEC 60904-9

lBottom-illuminated design, adjustable guide ways distance, easy to operate, install and integrate with automatic system

lInfrared temperature measurement and automatic coefficient correction

lSimultaneously test 9 key electric parameters and I-V / P-V curves; the sorting pattern is settable

lThe product is Convenience with the with the production line which can be adjusted and can be jointed perfectly

 Optical Parameters of Solar Simulator

Model

Test Area

Pulse Width

Spectrum 

Match

Non-uniformity

Instability

LTI

STI

OEM36SA02

2200mm*2700mm

10ms

A

≤2%

≤2%

A

Electric Parameters

Measurement
Repeatability

≤0.2% (at constant conditions)
(at constant conditions)

Voltage Range

(0~1/10/50/100/150/200)V

Current Range

0~10mA/100mA/1A/10A

Test Resolution

1/212

 

Other Parameters

Mechanical Data

MTC:400Kg;

W*D*H:  2500mm*1500mm*2050mm

PLG:150kg;
W*D*H: 600mm*600mm*1600mm

Power Supply

220VAC±10%,20A,50/60Hz,
Single Phase

Note:All the parameters depend on the models.